Environmental parameters 环境要求 | |
Subsurface 地面 | vibration-free and level 无振动且水平 |
Ambient temperature during operation 工作温度 | +20°C to +30°C |
Ambient storage temperature 存放温度 | +5°C to +40°C |
Relative humidity limit values during operation 湿度 | 10%- 70% non condensing 10%- 70%无结露 |
Distance between wall and back of machine 设备离墙距离 | approx. 1m 大约1米 |
Location altitude 地域海拔 | </= 1000 m above sea level 海拔1000m以下 |
Electrical Power 电气要求 | |
Power supply 电源要求 | 220±10% VAC, 50/60 Hz, 13 A |
Average Consumption 功耗 | 1.6 kW |
Dimensions of machine 设备尺寸 | |
W*H*D 宽*高*深 | 760mm x 1700mm x 1600mm |
Weight重量 | 350Kg |
Installation site
The site where the laser system will be installed must be level and vibration-free. In areas with vibrations make sure to provide suitable vibration buffers! 设备安装位置需要水平且无振动,如果环境有振动需要提供合适的减震装置!
This machine shall keep away from electromagnetic interference source(s), and the machine shall be grounded properly and effectively设备应远离干扰源,同时设备机壳一定可靠接地;
The machine should be store in a clean, dry, ventilated room with a temperature and RH required .
设备安装环境要尽可能保持清洁,保证良好的通风和散热,以及合适温湿度;
Equipment working environment not too wet, too high humidity can cause electrical breakdown or lighter and damage to equipment设备工作环境不能太潮湿,过高的湿度会引起电器击穿或打火而损伤设备;
Due to the laser there is risk of fire and explosion. To avoid risk of fire, never install the laser system in locations exposed to fire and explosion hazards, Keep away from corrosive material and heat. 加工过程要产生高温和火花,设备安装场地必须远离易燃、易爆、腐蚀物品。
Trouble 问题 | Possible cause 可能原因 | Solution 解决方案 |
有激光但不能标刻 Mark failure but laser is ok | No signal from computer 计算机信号没接通 | Check with another cable of P2 laser control port if possible. 检查计算机和P2激光控制电缆是否接好,可以尝试更换一根。 |
Galvo scanner failure 振镜故障 | Check red guide light moving by full path preview mode 观察红光移动通过全路径预览模式。 | |
Laser path is off-centre 光路偏离中心 | Adjust the laser path to lens centre 调整光路到镜片的中心 | |
Laser focus is not located on the workpiece surface 焦距没对准 | Adjust the z axis for right focus 改变调整Z轴到正确焦点位置 | |
Laser failure 无激光 | Check safety reset button 检查安全复位开关 | Blue light off is right status 蓝灯灭是正确状态 |
Check maintenance switch 检查维修开关 | maintenance switch off is right status 维修开关处于off是正确状态 | |
Laser failure 激光器故障 | Contact manufacture 通知生产厂家 | |
Wrong parameter setting 软件设置不当 | Check power and frequency setting 检查激光功率和频率设定 | |
Mark failure 不能打标 | electromagnetic interference 电磁干扰 | Restart equipment ,keep away from electromagnetic interference source 重启电脑,远离电磁干扰源 |